HD TECHNICAL CHARACTERISTIC
Specifications ................................................................... DIN VDE 0627
...................................................................................................DIN VDE 0110
Standards ..................................................................................DIN 43 652
............................................................................................ CECC 75 301-801
Number of contacts....................................7,8,15,25,40,50(2x25),64,
............................................................................80(2x40),128(2x64) + PE
INSERTS
Working current .......................................................................... 10A max
(See current carrying capacity)
Working voltage .................................................................... (8D is 50V)
.............................................................................250V, Insulation group C
Test voltage urms .....................................................4KV(8D is 0.8KV)
Pollution degree .........................................................................................2
Insulation resistance ....................................................................... ≥1010Ω
Material .............................................. Polycarbonate or Polybutylece
Temperature range ...........................................-40°C... +100°C/125°C
Flammability acc. to UL94 ..................................................................V0
Working voltage acc. to UL/CSA.................................................600V
Mechanical working life-mating cycles.......................................≥500

CONTACTS
Material ...................................................................................Copper alloy
Surface ..........................................................................Hard silver-plated
............................................................................................Hard gold-plated
Contact resistance ............................................................................≤3mΩ
Terminal ............................................................................. Crimp terminal
................................................................................................Rolled terminal
- mm2 ........................................................................................ 0.15-2.5mm2
- AWG .....................................................................................................26-14
HOODS/HOUSINGS
Material ...................................................................... Die cast aluminium
Surface ......................................................Powder-coated (RAL 7037)
Locking element.............................Stainless steel, steel-zinc plated
Temperature range ......................................................... -40°C... +125°C
Degree of protection acc. to DIN40 050 ....................................IP65

CURRENT CARRYING CAPACITY
The current carrying is limited by maximum temperature of materials for inserts and contacts including terminals. Control and test procedures according to DIN IEC 60512-3.

HDD TECHNICAL CHARACTERISTIC

Specifications ...............................................................DIN EN 60 664-1
................................................................................................. DIN EN 61 984
Number of contacts...........................................16,24,42,72,84(2x42),
................................................................................................144(2x72) + PE
INSERTS
Working current .......................................................................... 10A max
(See current carrying capacity)
Working voltage ..........................................250V, Insulation group C
Test voltage urms .............................................................................2.5KV
Pollution degree .........................................................................................2
Insulation resistance ....................................................................... ≥1010Ω
Material ............................................................................... Polycarbonate
Temperature range ...........................................-40°C... +100°C/125°C
Flammability acc. to UL94 ..................................................................V0
Working voltage acc. to UL/CSA................................................. 500V
Mechanical working life-mating cycles.......................................≥500

CONTACTS
Material ...................................................................................Copper alloy
Surface ..........................................................................Hard silver-plated
............................................................................................Hard gold-plated
Contact resistance ............................................................................≤3mΩ
Terminal ............................................................................. Crimp terminal
................................................................................................Rolled terminal
- mm2 ........................................................................................0.14-2.5mm2
- AWG .....................................................................................................26-14

HOODS/HOUSINGS
Material ...................................................................... Die cast aluminium
Surface ......................................................Powder-coated (RAL 7037)
Locking element.............................Stainless steel, steel-zinc plated
Temperature range ......................................................... -40°C... +125°C
Degree of protection acc. to DIN40 050 ....................................IP65

CURRENT CARRYING CAPACITY
The current carrying is limited by maximum temperature of materials for inserts and contacts including terminals. Control and test procedures according to DIN IEC 60512-3.

 